+91 932-330-9519
Power Consumption Calculator Click Here
    19.98% OFF
  • APC Back-UPS BE850M2, 850VA, 2 USB charging ports, 120V

APC Back-UPS BE850M2, 850VA, 2 USB charging ports, 120V

3 years repair or replace
  • M.R.P.: ₹7,497.00
  • Price: ₹5,999.00 In Stock

  • Ex Tax: ₹7,078.82

Technical Specifications:

Overview
Lead time Usually in Stock General
provided equipment User manual
USB cable
Number of tare power 7 W
Number of power module free slots 0
Number of power module filled slots 0
redundant No
UPS size WS
Physical cable length 1.52 m
colour Black
depth 10.5 cm
height 13.9 cm
mounting preference No preference
net weight 4.1 kg
mounting mode Not rack-mountable
two post mountable 0
USB compatible No
width 32.7 cm
Input
network frequency 50/60 Hz +/- 3 Hz auto-sensing
plug standard NEMA 5-15P
input voltage limits 92…139 V
number of cables 1
input voltage 120 V
Output rated power in W 450 W
Maximum configurable power in W 450 W
output frequency 50/60 Hz +/- 3 Hz sync to mains
UPS type Standby
Wave type Stepped approximation to a sinewave
nb of power socket outlets 6 NEMA 5-15R 3 NEMA 5-15R surge
curve equation Efficiency
curve fixed loss 0.0065
curve load maximum 100 %
curve load minimum 1 %
curve proportional loss 0
curve square loss 0.006
curve X-axis maximum 100 %
curve test cond ID Curve fit of data measured in accordance with the US DOE Test Procedure for Uninterruptible Power Supplies. All measurements taken in normal mode(s), at typical environmental conditions, with 120V/60Hz electrical input and balanced resistive load (PF = 1.0) output.
curve X-axis minimum 0 %
curve X-axis title Load
curve X-axis units Percentage
curve Y-axis maximum 100 %
curve Y-axis minimum 50 %
curve Y-axis title Efficiency
curve Y-axis units Percentage
graph display 1
output voltage 120 V
Maximum configurable power in VA 850 VA
rated power in VA 850 VA
Transfer time 6 ms typical : 10 ms maximum
Conformance product certifications California Energy Commission (CEC) CTUVus
standards CSA C22.2 No 107.3 FCC part 15 class B UL 1778
equipment protection policy Lifetime : $75000
Environmental ambient air temperature for operation 0…40 °C
relative humidity 0…95 % non-condensing
operating altitude 0…10000 ft
ambient air temperature for storage -15…45 °C
Storage Relative Humidity 10…90 %
storage altitude 0.00…15240.00 m
acoustic level 45 dBA
show note OP temperature No
Batteries & Runtime battery type Lead-acid battery
number of battery filled slots 0
number of battery free slots 0
Battery recharge time 8 h
liquid value 0
battery curve B
battery charger power 13 W rated
Battery power in VAH 102 VAh capacity 104 VAh runtime
battery life 2…5 year(s)
Battery graph comments This graph is based on actual measured runtime data. All measurements were taken with new, fully charged batteries and a balanced resistive load (PF = 1.0). Actual runtimes may vary from the values of this graph. Actual runtimes are dependent on several variables including battery age, battery charge level, environmental conditions and characteristics of the connected load.
extended runtime 0
Communications & Management control panel LED status display with on line : on battery : replace battery and building wiring fault alarm
Alarm when on battery distinctive low battery alarm : overload continuous tone alarm
Surge Protection and Filtering Surge energy rate 354 J
Packing Units Package 1 Weight 4.4 kg
Package 1 Height 19.6 cm
Package 1 width 41.6 cm
Package 1 Length 16.8 cm SCC14 10731304325267
Number of Units in Package 2 2
Package 2 Weight 9.80 kg
Package 2 Height 429.01 mm
Package 2 width 349.00 mm
Package 2 Length 219.46 mm
Number of Units in Package 3 80
Package 3 Weight 414 kg
Package 3 Height 4 cm
Package 3 width 120 cm
Package 3 Length 120 cm
Pallet unit layers 16
Pallet layers 5
Contractual warranty
Warranty 3 years repair or replace

Write a review

Note: HTML is not translated!
    Bad           Good